Smooth Sandwich Panel | Exterior Insulated Panel

PANEL MASTER- C

MASTER-C panels are continuous production line prefabricated panels, and are composed of two faces of prepainted galvanized steel, bonded to a core of rigid polyurethane (PUR) or polyisocyanurate (PIR) foam, forming a sandwich type element with tongue and groove joints.

MASTER-C panels are specially designed for use in all types of roofs, both for industrial construction and for modular or commercial buildings.

Installation is very simple, and provides total watertightness (roof slopes of over 4%).

MASTER-C panels have a tongue and groove jointing system with a steel cover cap that hides and protects the fasteners and ensures the watertightness of the system. Regarding the external profile of the panel, there are two different designs, with a choice of two-rib panels and three-rib panels, both available in seven different thicknesses, with two different interior rib designs and a wide range of colours. Additionally, MASTERPANEL also offers the option of panels manufactured with PIR (polyisocyanurate) self-extinguishing foam with a B-s1, d0 certification under Euroclasses (UNE-EN 13501).

Technical specifications

Panel thickness 30, 40, 50, 60, 80, 100, 120mm.
Cover Width 1.000mm
Length Up to 16,000 mm (max. recommended 13,000 mm)
Field of application Roofing
Outer face thickness: 0,4/0,5/0,6/0,7mm
Inner face thickness: 0,4/0,5/0,6/0,7mm
Coatings (see section on Finishes):
  • Polyester 25um
  • PVDF 25um/35um
  • PU 55um (Granite® HDX/PUPA 55)
  • Imitation wood (inner face)
  • PVC 120um (foodsafe)
Outer ribbing Two ribs / Three ribs
Inner ribbing Standard / Flat
Core type
  • Polyurethane (PUR)
  • Polyisocyanurate (PIR)
Core Density 40kg/m³
Thermal Conductivity 0,021 W/m K
Tensile strength >0,060Mpa
Compressive strength >0,100Mpa
Flexural strength >0,100Mpa
Reaction to fire Cs3d0 / Bs1d0
Classification for roof exposed to external fire Broof

Dimensions in mm.

Joint detail

For other fixing options: see Panel construction details, technical advice tab of this website.

Panel thickness Weight Thermal transmittance (U-value) Thermal resistance (R-value)
mm kg/m2 w/m2 k kcal/m2 h ºC m2k/w Hr f² °F/BTU
30 9,61 0,67 0,58 1,50 8,49
40 10,00 0,51 0,44 1,95 11,06
50 10,39 0,41 0,36 2,42 13,74
60 10,78 0,35 0,30 2,90 16,45
80 11,56 0,26 0,22 3,85 21,84
100 12,34 0,21 0,18 4,80 27,20
120 13,12 0,17 0,15 5,74 32,55

Calculations according to EN14509, measuring the surface resistance according to horizontal flow and omitting the influence of the profiled faces. Losses in bolted connections must be calculated by the designer.

FUNCTIONS AND BENEFITS OF MASTER-C PANELS

  • Efficient thermal insulation capacity
  • High mechanical strength
  • The fasteners are hidden and protected
  • Exceptional dimensional stability
  • Watertight against water vapor
  • Resistant to aggressive environments
  • A versatile material that allows any configuration
  • Quick to install and easy to maintain (easy to clean)
  • Easily removable and can be reused
  • Made-to measure, avoids waste
  • Made with recyclable materials

REACTION TO FIRE

Permissible overloads (kg/m2)

Panel thickness
mm
(L) span distance in cm. Calculations made on 0,50mm./0,50mm panel.
150 175 200 225 250 275 300 325 350 375 400 450
30 331 233 172 168 137
40 409 297 225 213 176 149 127 109
50 489 364 281 260 218 186 160 139 122 107
60 432 339 309 261 224 194 170 150 133 119 96
80 458 410 350 304 266 235 209 187 168 138
100 442 386 340 302 271 243 220 182
120 470 416 371 334 301 274 228

Evenly distributed pressure overload for 2 spans (3 supports).
Calculated for a Service Limit State of deformations L / 200. According to EN14509.
Overloads not factored. The designer must carry out the calculations in accordance with the applicable regulations.
Admissible overloads valid for three-rib profile. For admissible overloads of the two-rib profile, consult our technical department.

Colour chart

descargar button
DOWNLOAD COLOUR CHART
  • Colours in this catalogue are approximate.
  • Possibility of manufacturing in other colours on request.

Guide to select the right finish

descargar button
DOWNLOAD COATING GUIDE

In order to choose the right prepainted finish for each use, the planner responsible for the design of the project must take into account both the incidence of UV rays and the exposure to corrosive environments of the building or project.

  • Corrosion resistance of the paint system To determine the corrosion resistance of a paint system, it is subjected to the salt spray test. This test evaluates the appearance of corrosion after a number of hours in a saline mist chamber. The results provide each paint scheme with an RC corrosion resistance value, from RC1 to RC5, with RC1 being the lowest value. This means that those RC3 rated paint schemes have shown their suitability for environments rated C3 or lower.
  • Resistance to UV radiation of the paint system To determine the UV resistance of a paint system, it is subjected to the QUV accelerated aging test. This test evaluates the loss of gloss and colour over time due to UV rays. The results provide each paint scheme with a UV resistance value RUV, from RUV1 to RUV4, with RUV1 being the lowest value.
  • Classification of environments DESCRIPTION
DESCRIPTION OF CORROSIVE CATEGORIES FOR EXTERNAL ENVIRONMENTS
C1 Very low
C2 Low: Areas with low level of contamination. Mainly rural or industrial areas without incidence by sulphur dioxide.
C3 Moderate: Urban and industrial areas with low sulphur dioxide (SO2) pollution and coastal areas with low salinity (from 10 km to 20 km from the sea).
C4 High: Industrial areas with moderate contamination by sulphur dioxide (SO2) and coastal areas with moderate salinity (from 3 km to 10 km from the sea).
C5 I Very high: Industrial areas with very aggressive atmospheres and high contamination by sulphur dioxide (SO2)
C5 M Very high: Coastal and maritime areas with high salinity (from 1 km to 3 km from the sea).
DESCRIPTION OF THE CATEGORIES OF UV RESISTANCE FOR EXTERNAL ENVIRONMENTS

Area 1: Areas not exposed to UV radiation. Indoor use without any radiation.
Area 2: Areas with low exposure to UV radiation or without special colour maintenance requirements.
Area 3: Areas with moderate exposure to UV radiation.
Area 4: Areas with high exposure to UV radiation or with special colour maintenance requirements.

Choice of finishes for different environments

Once the category of the environment is known, the person responsible for the design must decide on the painting system:

1) The suitable paint system needs to be determined in terms of corrosion. The following table can be used as a guide.

2) The suitable paint system in terms of UV radiation have to be determined. The following table can be used as a guide.

3) A suitable paint system should be chosen in terms of both corrosion resistance and UV resistance. The following cases can be used as a guide.

The data stated in the tables is informative and does not constitute a guarantee of the material. You should contact Masterpanel about any applications which require a guarantee for the steel in the panels.

FINISHES

descargar button
DOWNLOAD FINISHES

Standard finish: Polyester 25 um. Other finishes available on request. Guide values to be taken as a reference. Consult for guarantees.

In order to provide you with information about this product, we offer you all the documentation concerning Master C / Roofing panels.

descargar button
Technical specifications
descargar button
Catalogue
descargar button
Quality certificate
descargar button

Certificates of reaction to fire

descargar button
BIM
descargar button
DWG

MasterPanel offers our clients a technical department to support your designers and Project Management. Our building system section provides support from the initial concept of the project to the installation and subsequent maintenance.

This advice may include:

  • Proposals for appropriate technical solutions for each project.
  • Providing support regarding the cutting, quantifications of the panels and necessary accessories.
  • Support and technical information for the training of fitters.
  • We provide plans and sketches of the most common technical details.
  • Technical support in the correct installation of our panels, forming a team with the Project Management
  • Panels must always be transported on flatbed vehicles.
  • Panels will always be packed with polystyrene blocks at the base to avoid damage.
  • Panel stacks should never exceed 2.60 m. high (including polystyrene blocks, accessories, cover caps, trims, etc).
By truck
In containers
DOWNLOAD RECOMMENDATIONS
descargar button
DOWNLOAD

REQUEST A QUOTE

    The data controller is MASTER PANEL SL. The purpose of data collection is to be able to answer your questions, without disclosing your data to third parties. You have the right to know what information we have about you, correct it or delete it as explained in our Privacy Policy.