MG 60/220
- Composite floor Deck
- Non-composite floor Deck
A profile specially designed for the construction of mixed concrete-steel floors for industrial, residential and commercial buildings. It can be used as a composite slab metal profile or as a non-composite floor deck in concrete slabs. It has a rib height of 60 mm, usable width of 880mm, and includes countersunk embossments on the side of the ribs. It drastically reduces the use of struts, enables immediate transit, requires little labour, is quick to install and involves less dead load on the structure.
Product certified according to UNE-EN 10340: 2008 and UNE-EN 1090: 2019 standards.
End use | Composite fl oors and permanent formwork |
Steel type | Standard S250GD (other types of steel on request) |
Rib height | 60mm |
Rib spacing | 220mm. |
Usable width | 880mm. |
Thickness | From 0.8 mm to 1.2mm |
Length | On request (maximum 14 m). |
The nature of the supporting structure can be metallic, concrete or masonry. The supports on it must comply with the premises established by the EUROCODE.
In order to provide you with information about this product, we provide you with all the documentation relating to MG 60/220 Composite and Non-composite floor Deck.
Magon Aceros offers its clients a technical department to provide support to designers and site management. We offer support for our construction system from the gestation of the project to its installation and subsequent maintenance.
The packages are individually labeled, ensuring their traceability, and we provide a Quality Certifi cate (if requested) for pre-painted material according to the UNE-EN-10169 standard and for galvanized base material according to the UNE-EN-10346 standard. Each package is bound transversely with nylon or polyester strap, which allows stacking, without deformation of the lower packages. Finally, the products are packed with nylon or polyester straps, so that the packages can be handled both by weight and size.
The material must be handled by means of slings for unloading, placing it in such a way that the sides of the packages are not damaged (with use of an unloading cradle) and at the correct distance so that the suspended load does not move.
Staff must always handle the sheets and profiles with safety gloves
Appropriate tools should be used to remove the sheets and profile packaging.
During transport, the packages must be well stacked to prevent the load from shifting, placing them in such a way as to avoid the accumulation of water in the event of rain. Likewise, they must travel in covered transport, MAGON ACEROS is exempt from all responsibility if these recommendations are not followed.
The packages must always be covered and ventilated, preventing them from touching the ground by means of wooden blocks or similar materials, and stacked at an angle. As the material is sensitive to humidity, condensation and rain, the infiltration of water can lead to the formation of “white rust” which, although not harmful to the material, can mar the material’s appearance.
When damage that affects the coating occurs during the handling of the panels, proceed as follows:
When the zinc coating is visible:
When painting over pre-lacquered paint:
For proper maintenance of our material, we recommend cleaning any residue that could cause water retention on the roof (mould, vegetation, any type of debris …).
In addition, we recommend maintaining the drainage of rainwater and washing the wall panels and roofs (if detergent is used, it must be with a neutral PH).